				<item>
				<title>Power Quality Solutions Products</title>
				<link>https://www.p2power.co.in/power-quality-solution-products.htm</link>
				<guid>https://www.p2power.co.in/power-quality-solution-products.htm</guid>
				<pubDate>Fri, 20 Mar 2020 00:00:00 +0530</pubDate>
				<description></description>
				</item>
				<item>
				<title>Voltage Regulation Solution Products</title>
				<link>https://www.p2power.co.in/voltage-regulation-solution-products.htm</link>
				<guid>https://www.p2power.co.in/voltage-regulation-solution-products.htm</guid>
				<pubDate>Fri, 20 Mar 2020 00:00:00 +0530</pubDate>
				<description></description>
				</item>
				<item>
				<title>Single Phase Active Harmonic Filter</title>
				<link>https://www.p2power.co.in/active-harmonic-filter.htm</link>
				<guid>https://www.p2power.co.in/active-harmonic-filter.htm</guid>
				<pubDate>Thu, 17 Jul 2025 00:00:00 +0530</pubDate>
				<description>Input voltage: single phase 220V to 240V AC. Frequency: 50 Hz or 60 Hz. Harmonic compensation range: up to 50th harmonic order. Rated current: varies by model, typically from 5 A to 100 A. Control method: digital signal processor (DSP) based real-time harmonic detection and filtering. Response time: milliseconds to microseconds. Power factor correction capability: improves power factor close to unity. Protection features include overcurrent, short circuit, overvoltage, and thermal protection. Cooling is typically forced air or natural convection. Mounting options include wall-mounted or panel-mounted. Operating temperature ranges from -10&amp;deg;C to +50&amp;deg;C. Humidity tolerance is up to 95% non-condensing. Communication protocols such as Modbus or Profibus may be supported for monitoring and control. Compliance adheres to IEC standards and relevant industry norms</description>
				</item>
				<item>
				<title>Three Phase Active Harmonic Filter</title>
				<link>https://www.p2power.co.in/3-level-active-harmonic-filter.htm</link>
				<guid>https://www.p2power.co.in/3-level-active-harmonic-filter.htm</guid>
				<pubDate>Thu, 17 Jul 2025 00:00:00 +0530</pubDate>
				<description>Input voltage: Three phase, typically 380V to 480V AC. Frequency: 50 Hz or 60 Hz. Harmonic compensation range: Up to 50th harmonic order. Rated current: Depends on model, ranging from 10 A to several hundred amperes. Control method: Digital signal processor (DSP) based real-time harmonic detection and filtering. Response time: Milliseconds to microseconds. Power factor correction capability: Improves power factor close to unity. Protection features: Overcurrent, short circuit, overvoltage, and thermal protection. Cooling: Forced air cooling with fans. Mounting: Floor or panel mounted. Operating temperature: -10&amp;deg;C to +50&amp;deg;C. Humidity: Up to 95% non-condensing. Communication: Optional communication protocols like Modbus, Profibus for monitoring and control. Compliance: IEC standards and relevant industry norms.</description>
				</item>
				<item>
				<title>Multi-Level Active Harmonic Filter</title>
				<link>https://www.p2power.co.in/multi-level-active-harmonic-filter.htm</link>
				<guid>https://www.p2power.co.in/multi-level-active-harmonic-filter.htm</guid>
				<pubDate>Tue, 05 Feb 2019 00:00:00 +0530</pubDate>
				<description>Features Fast 32 bit digital signal processor Multi-Level converter architecture Direct Connection to 575V and 690V loads Synchronous Rotating Frame Principal for best performance Ultra fast compensation Proven performance on welding Harmonic Attenuation of &amp;gt;98% High Efficiency of &amp;gt;98% Selective Harmonic compensation Leading/Lagging Reactive Power Compensation Negative Sequence Compensation (load balancing) 15 possible Priority Selection settings for maximum flexibility Smart auto foldback to avoid over loading of filter 7&quot; touch screen display Ethernet based remote monitoring MODBUS RTU, USB, SD Card Internal CAN Communication Closed Loop &amp;amp; Open Loop operation Paralleling of upto 32 filters for higher capacity Operator Activity Log &amp;gt;2,00,000 time stamped events can be logged in internal NAND memory &amp;nbsp; Benefits Compliance with prescribed harmonic limits - No penalty Unity Power Factor - higher savings Reduced energy (kVAh) charges - higher savings Reduced peak demand charges - higher savings Reduced fuel consumption in generators - higher savings Ultra fast compensation - effective with fast fluctuating load Optimum capacity utilization of electrical infrastructure Optimum capacity utilization of backup generators Improved voltage profile Reduced risk of transformer failure - higher uptime Reduced risk of equipment failure - higher uptime Increased operational reliability - higher uptime Compact footprint Indigenous design, low maintenance and prompt service</description>
				</item>
				<item>
				<title>Three Phase 415 V Hybrid Power Factor Correction Panel</title>
				<link>https://www.p2power.co.in/hybrid-power-factor-correction-panel.htm</link>
				<guid>https://www.p2power.co.in/hybrid-power-factor-correction-panel.htm</guid>
				<pubDate>Thu, 17 Jul 2025 00:00:00 +0530</pubDate>
				<description>Input voltage: Three phase 415 V AC. Power factor correction type: Hybrid (combination of passive and active correction). Components include capacitors, inductors, and power electronic devices. Rated current: Depends on panel size, typically from 10 A to several hundred amperes. Operating frequency: 50 Hz or 60 Hz. Control method: Automatic with microprocessor or PLC-based control. Protection features: Overcurrent, short circuit, and overload protection. Power factor improvement range: Typically from 0.7&amp;ndash;0.95 up to 0.98 or higher. Mounting: Floor mounted or panel mounted. Cooling: Natural or forced ventilation. Operating temperature: -10&amp;deg;C to +50&amp;deg;C. Humidity: Up to 90% non-condensing. Standards compliance: IEC or relevant local standards.</description>
				</item>
				<item>
				<title>Detuned Reactor</title>
				<link>https://www.p2power.co.in/detuned-reactor.htm</link>
				<guid>https://www.p2power.co.in/detuned-reactor.htm</guid>
				<pubDate>Tue, 05 Feb 2019 00:00:00 +0530</pubDate>
				<description>Features Special design for reduced heating Vacuum Impregnated Rugged design for harsh environments Thermal protection against over temperature Low Noise &amp;nbsp; Benefits Remove harmonic amplification Increase the life of capacitors Avoid harmonic resonance in the network Reduce cable and transformer losses Avoid over current during hard switching of capacitors</description>
				</item>
				<item>
				<title>Dynamic Voltage Regulator</title>
				<link>https://www.p2power.co.in/dynamic-voltage-regulator.htm</link>
				<guid>https://www.p2power.co.in/dynamic-voltage-regulator.htm</guid>
				<pubDate>Thu, 17 Jul 2025 00:00:00 +0530</pubDate>
				<description>Input voltage range typically 140V to 280V AC depending on the model. Output voltage is a stable regulated voltage, usually 220V with &amp;plusmn;1-3% variation. Frequency supported is 50Hz or 60Hz. Regulation is automatic voltage regulation (AVR) using a servo motor or electronic control. Response time to voltage fluctuation is typically less than 0.1 seconds. Capacity or power rating ranges from 1 kVA to several hundred kVA. Cooling is done by natural air or forced air cooling with a fan. Protection features include overload protection, short circuit protection, under-voltage and over-voltage protection. Available in single phase and three phase versions. Efficiency generally exceeds 95%. Mounting options include floor standing or panel mounted. Control can be manual or digital display with monitoring options. Operating temperature ranges from -10&amp;deg;C to +50&amp;deg;C and humidity tolerance is up to 90% non-condensing.</description>
				</item>
				<item>
				<title>Three Phase Automatic Servo Stabilizer</title>
				<link>https://www.p2power.co.in/servo-stabilizer.htm</link>
				<guid>https://www.p2power.co.in/servo-stabilizer.htm</guid>
				<pubDate>Thu, 17 Jul 2025 00:00:00 +0530</pubDate>
				<description>Input Voltage Range: 300V &amp;ndash; 470V AC (Phase to Phase, customizable range) Output Voltage: 400V &amp;plusmn; 1% (adjustable) Capacity Range: 5 KVA to 500 KVA (as per requirement) Phase Type: Three Phase, Four Wire System Stabilization Type: Servo Motor Controlled with Buck/Boost Transformer Correction Speed: 10&amp;ndash;50 Volts per Second (varies by capacity) Frequency: 50Hz &amp;plusmn; 5% Efficiency: &amp;ge; 95% Cooling Type: Natural Air Cooled / Oil Cooled (based on capacity) Mounting: Floor Mounted (Indoor or Outdoor Cabinet options) Protection Features: Overload, Short Circuit, Over/Under Voltage, Phase Reversal Display: Digital Volt/Amp Meter, LED Indicators for Input/Output Status Control System: Microcontroller-Based Automatic Operation Applications: CNC Machines, Medical Equipment, Printing Press, Industrial Units, Commercial Complexes Warranty: 12&amp;ndash;24 months standard Compliance: ISO / CE Certified, IS Standard Tested</description>
				</item>
				<item>
				<title>DC Charger</title>
				<link>https://www.p2power.co.in/dc-charger.htm</link>
				<guid>https://www.p2power.co.in/dc-charger.htm</guid>
				<pubDate>Tue, 09 Feb 2021 00:00:00 +0530</pubDate>
				<description></description>
				</item>
				<item>
				<title>AC Charger</title>
				<link>https://www.p2power.co.in/ac-charger.htm</link>
				<guid>https://www.p2power.co.in/ac-charger.htm</guid>
				<pubDate>Tue, 09 Feb 2021 00:00:00 +0530</pubDate>
				<description></description>
				</item>
				<item>
				<title>Ev Infra &amp; E-mobility Solutions</title>
				<link>https://www.p2power.co.in/ev-infra-e-mobility-solutions.htm</link>
				<guid>https://www.p2power.co.in/ev-infra-e-mobility-solutions.htm</guid>
				<pubDate>Thu, 02 Apr 2020 00:00:00 +0530</pubDate>
				<description></description>
				</item>
				<item>
				<title>Brochure</title>
				<link>https://www.p2power.co.in/.htm</link>
				<guid>https://www.p2power.co.in/.htm</guid>
				<pubDate>Thu, 18 Feb 2021 00:00:00 +0530</pubDate>
				<description></description>
				</item>
				<item>
				<title>AC Type 2 Charger</title>
				<link>https://www.p2power.co.in/ac-type-2-charger.htm</link>
				<guid>https://www.p2power.co.in/ac-type-2-charger.htm</guid>
				<pubDate>Sat, 26 Feb 2022 00:00:00 +0530</pubDate>
				<description>Model: Lite/ Basic/Ultra Input Power- 3.3kW, 7.2kW/11kW, 22kW Input Voltage- 230V AC single phase/415V AC 3 Phase Communication: Wifi, BT, RS485, LAN/4G/OCPP 1.6V</description>
				</item>
				<item>
				<title>Thyristor Switching Module</title>
				<link>https://www.p2power.co.in/thyristor-switching-module.htm</link>
				<guid>https://www.p2power.co.in/thyristor-switching-module.htm</guid>
				<pubDate>Sat, 26 Feb 2022 00:00:00 +0530</pubDate>
				<description>It allows compensation of very high fluctuating reactive power demand. This system uses switching algorithm to toggle On/Off capacitor groups for required compensation with connection and disconnection of capacitor to and from the network at active zero potential crossing even in presence of harmonics.</description>
				</item>